Your browser is not supported. For the best experience, you should upgrade to a modern browser with improved speed and security.

14 SEER 36,000 BTU Heat Pump Condenser and Multi-Family Fan Coil Package

Item: MAQ36113MFFC

Included In This Bundle

  • Ductless 36000 Btuh Heat Pump Single Zone w/ Basepan Heater 208/230-1
    Item: 38MAQB36R--3
    MFR: 38MAQB36R--3
    Quantity: 1
  • 3 Ton Apartment Fan Coil
    Item: FMA4X3600AL
    MFR: FMA4X3600AL
    Quantity: 1

* Required Fields

Store Inventory

Sign in to see real-time inventory at the stores closest to you.
What’s the price?
Sign in for pricing.

About This Product

Product Info

Description

14 SEER 36,000 BTU Heat Pump Condenser and Multi-Family Fan Coil Package
Warning: this product contains a chemical known to the State of California to cause cancer. P65Warnings.ca.gov

Specifications

BrandCarrier Enterprise
Prop 65Yes

Bundle Components

Ductless 36000 Btuh Heat Pump Single Zone w/ Basepan Heater 208/230-1

Item: 38MAQB36R--3

Description

38MAQB36R--3
38 = OUTDOOR UNIT
MA = MODEL
Q = HEAT PUMP SYSTEM TYPE
B = 1:1 MAXIMUM NUMBER OF FAN COIL UNITS THAT CAN BE CONNECTED TO THE OUTDOOR UNIT
36 = 3 TON NOMINAL CAPACITY
R = HIGH HEAT UNIT TYPE
-- = NOT USED
3 = 208/230-1-60

The 38MA*R series ductless split systems are a matched combination of an outdoor condensing unit and an indoor fan coil unit connected only by refrigerant tubing and wires.The ductless system permits creative solutions to design problems such as:

  • Add-ons to current space (an office or family room addition)
  • Special space requirements
  • When changes in the load cannot be handled by the existing system
  • When adding air conditioning to spaces that are heated by hydronic or electric heat and have no ductwork

Historical renovations or any application where preserving the look of the original structure is essential.The ideal compliment to your ducted system when it is impractical or prohibitively expensive to use ductwork. The compact indoor fan coil units take up very little space in the room and do not obstruct windows. The fan coils are attractively styled to blend with most room decors. Advanced system components incorporate innovative technology to provide reliable cooling performance at low sound levels.

LOW SOUND LEVELS
When noise is a concern, the ductless split systems are the answer.The indoor units are whisper quiet. There are no compressors indoors, either in the conditioned space or directly over it, and there is none of the noise usually generated by air being forced through ductwork.
When sound ordinances and proximity to neighbors demand quiet operation, the 38MA*R unit is the right choice. The advanced, horizontal airflow design distributes air more evenly over the coil.
SECURE OPERATION
If security is an issue, outdoor and indoor units are connected only by refrigerant piping and wiring to prevent intruders from crawling through ductwork. In addition, since 38MA*R units can be installed close to an outside wall, coils are protected from vandals and severe weather.
FAST INSTALLATION
This compact ductless split system is simple to install. A mounting bracket is standard with the indoor units and only wire and piping need to be run between the indoor and outdoor units (High Walls).These units are fast and easy to install ensuring minimal disruption to customers in the home or workplace. This makes the 38MA*R ductless split systems the equipment of choice, especially in retrofit situations.
SIMPLE SERVICING AND MAINTENANCE
Removing the top panel on outdoor units provides immediate access to the control compartment, providing a service technician access to check unit operation. In addition, the draw-thru design of the outdoor section means that dirt accumulates on the outside surface of the coil. Coils can be cleaned quickly from the inside using a pressure hose and detergent.
On all indoor units, service and maintenance expense is reduced due to easy-to-use cleanable filters. In addition, these systems have extensive self-diagnostics to assist in troubleshooting.
BUILT-IN RELIABILITY
Ductless split system indoor and outdoor units are designed to provide years of trouble-free operation.
The indoor units include protection against freeze-up and high evaporator temperatures on heat pumps.
The condensing units on heat pumps are protected by a three minute time delay before the compressor starts the over-currentprotection and the high temperature protection.
INDIVIDUAL ROOM COMFORT
Maximum comfort is provided because each space can be controlled individually based on usage pattern. The air sweep (in some indoor models) feature provided permits optimal room air mixing to eliminate hot and cold spots for occupant comfort. In addition, year-round comfort can be provided with heat pumps.
ECONOMICAL OPERATION
The ductless split system design allows individual room heating or cooling when required. There is no need to run large supply-airfans or chilled water pumps to handle a few spaces with unique load patterns. In addition, because air is moved only in the space required, no energy is wasted while air moves through the ducts.
EASY-TO-USE CONTROLS
The indoor units have microprocessor-based controls to provide the ultimate in comfort and efficiency. The user friendly wireless remote control provides the interface between the user and the unit.
ACCESSORIES
Customizing these ductless split systems to your application is easily accomplished. Adding a condensate pump accessory to the indoor fan coil provides installation flexibility.
OPTIONAL WIRED CONTROLLER
AGENCY LISTINGS
All systems are listed with AHRI (Air Conditioning, Heating & Refrigeration Institute), and ETL.

Specifications

Weight147.3 Pounds (lbs)
Width37.24 Inches (In)
Height31.89 Inches (In)
Country of OriginCHN
Length16.14 Inches (In)
BrandBryant,Carrier
CertificationsAHRI Certified
CFM2130
Circuit Breaker - Max Amps35
Circuit Breaker - Min Amps25
ColorGray
Cooling Capacity36000
Cooling Rated Capacity Btu/h36000
Cycle/Hertz60 Hz
EER8.6
Energy Star RatedYes
ETL ListedYes
Heating Capacity36000
HSPF8.5
InverterYes
Liquid Line FittingFlare
Liquid Line Size (OD)3/8"
Maximum Piping Length164'
Number of HVAC Zones1
PhaseSingle
Product Family38MAR
Prop 65Yes
Rated Load Amps17
RefrigerantR-410a
SEER16
Single ZoneYes
Sound Level (dBA)60.5
StageVariable
Suction Line FittingFlare
Suction Line Size (OD)5/8"
TierPerformance,Preferred™
Tonnage3
UL ListedNo
Voltage208-230 VAC
Zone Capability1 Zone

3 Ton Apartment Fan Coil

Item: FMA4X3600AL

Description

FMA4X3600AL
F = Fan Coil
M = Multi-Family / TYPE
A = Apartment / INSTALLATION TYPE
4 = Environmentally Balanced R-410a / REFRIGERANT
X = R-410a TXV & ECM Motor / METERING DEVICE / BLOWER TYPE
3600 = 36,000 BTUH = 3 Tons / NOMINAL CAPACITY
A = Marketing Revision / REVISION
L = Aluminum Coil / SALES CODE / FEATURES

FEATURES:
  • Upflow application only
  • Accessory field-installed electric heat kits available in 5, 7.5, or 10 kW
  • 208/230-1-60 supply voltage
  • Cabinet exterior is galvanized sheet metal
  • Cabinet air leakage rate below 1.4% when tested to ASHRAE Standard 193
  • Insulated for conditioned space (not to be installed in unconditioned spaces)
  • All Aluminum coils
FMA4P
  • For use with R-410A refrigerant utilizing standard piston
FMA4X
  • R-410A refrigerant, TXV standard
PERFORMANCE
  • PSC motor on all FMA4P
  • ECM motor on all FMA4X
  • Motor suspended on rubber grommets for quieter operation
  • Fresh air intake knockouts in cabinet
EASY TO INSTALL AND SERVICE
  • Units fits between standard stud spacings
  • All service access is located in the front
  • Primary and secondary drain connections exit from the bottom, access panel in bottom of cabinet
  • No return-air ductwork required in specific applications
  • Wall hanging brackets included with the unit
LIMITED WARRANTY*
  • 5 year parts limited warranty
  • -With timely registration, an additional 5 year parts limited warranty
* For residential applications only. See warranty certificate for complete details and restrictions, including warranty coverage for other applications.

Filter Size: 20" x 20" x 1" (Field Installed)

Specifications

Weight97 Pounds (lbs)
Width22 Inches (In)
Height39.5 Inches (In)
Country of OriginCHN
Length19 Inches (In)
Air FlowUpflow
Blower Motor HP1/2 HP
Blower Motor RPM1050
Blower Motor Speeds5 (Five)
Blower Motor TypeECM (Electronically Commutated Motor)
Blower Motor Watts529
BrandPayne,Carrier,Bryant
CFM900-1350
Circuit Breaker - Max Amps60
Circuit Breaker - Min Amps26
ColorBeige
Cooling Capacity36000
Cooling Rated Capacity Btu/h36000
Cycle/Hertz60 Hz
Electric Heat Range [kW]5-10
Energy Star RatedNo
ETL ListedYes
Filter Size20" x 20" x 1"
Heat Pump CompatibleYes
Liquid Line Size (OD)3/8"
Maximum Fuse Size15
Minimum Circuit Amps3.4
PhaseSingle
Product FamilyFMA4X
Prop 65Yes
Rated Current Amps2.7
Rated Load Amps2.7
RefrigerantR-410a
Suction Line Size (OD)3/4"
TierStandard
Tonnage3
UL ListedYes
Voltage208-230 VAC

Equipment Part List