About This Product

Product Info

Description

17 SEER 24,000 BTU Heat Pump Condenser and Fan Coil Package
Warning: this product contains a chemical known to the State of California to cause cancer. P65Warnings.ca.gov

Specifications

BrandCarrier Enterprise
Prop 65Yes

Bundle Components

1.5 - 3 Ton Residential Fan Coil Variable Speed Multipoise (Aluminum Coil)

Item: FV4CNF002L00

Description

STANDARD FEATURES

Environmentally Sound Refrigerant Technology
  • Puron®, chlorine-free, non-ozone depleting refrigerant
  • Thermostatic Expansion Valve (TXV) designed to maximize performance with Puron® refrigerant
Energy Efficient Operation
  • Electronically Commutating Motor (ECM) operates efficiently at all speeds
  • Maximizes efficiency of heating and cooling systems
  • Ultra low power consumption during fan only operation
Indoor Weather Control
  • Warm, comfortable heating air temperatures
  • Unmatched humidity control when paired with a humidity sensing thermostat
Airflow and Sound Technology
  • Diffuser air discharge section for high airflow efficiency and quiet, smooth operation
  • High duct static capability
  • Unique cabinet design that meets new stringent regulations for air leakage. Meets requirements of a 2%cabinet leakage rate when tested at 1.0 inches of static pressure
Condensate Control and Disposal Technology
  • Minimal standing waterless microbial growth for improved IAQ and reduced condensate line clogging and related condensate leakage
  • Condensate fittings relocated away from turbulent airflow patterns at the blower entrance for improved condensate control performance
  • Overflow feature for slope coil units allows condensate to exit the unit without damage to product under clogged primary and secondary line conditions
  • Tested for condensate disposal at conditions much more severe than those required by AHRI
  • Primary and secondary drain connections to comply with HUD
  • All pans constructed of an injection molded glass-filled polycarbonate engineered resin material, with brass drain connections.
  • High density, super thick cabinetry insulation with vapor barrier
  • Pre-painted galvanized sheet metal cabinet
Heat Transfer Technology
  • Grooved tubing
  • Lanced sine wave aluminum fins
  • Discreet refined counter-flow refrigerant circuitry
  • Bi-flow hard shut-off TXV metering device
Quality Assisting, Ease of Installation and Service Features
  • All units multipoise
  • Provision made for suspending from roof or ceiling joints
  • Modular cabinet on 003 to 006 units
  • Sweat connections for leak free service
  • Multiple electrical entry for application flexibility (high and low voltage)
  • Low voltage terminal strip, to safely hold connections within the cabinet
  • Cabinet construction features innovations designed to prevent cabinet sweating
Controls and Electrical Features
  • Easy Select™ Board to maximize comfort, efficiency, and safe heater airflow operation
  • Easy plug connection provided for quick installation of accessory heater packages
  • 40VA 208/230v transformer
  • Replaceable 5-amp blade-type auto fuse protects against transformer secondary short
Filter Features
  • Factory supplied filter
  • Cleanable polyester filter media
  • Filter “springs” out for easy access - no tools required
  • Newly improved filter rack area - filter door insulation added for an improved air seal

Specifications

Weight148 Pounds (lbs)
Width17.625 Inches (In)
Height42.6875 Inches (In)
Country of OriginVar
Length22.0625 Inches (In)
Air FlowMulti-Position
Blower Motor HP1/2 HP
Blower Motor RPM1050
Blower Motor SpeedsVariable
Blower Motor TypeECM (Electronically Commutated Motor)
Blower Wheel10.625" x 9.625"
BrandCarrier,Payne,Bryant
CasedYes
CertificationsUL Listed,AHRI
CFM1050
Circuit Breaker - Max Amps15
Circuit Breaker - Min Amps5.4
Coil TypeA Coil
ColorGray
Cooling Capacity36000
Cooling Rated Capacity Btu/h36000
Cycle/Hertz60 Hz
Electric Heat Range [kW]5-20
Energy Star RatedNo
ETL ListedNo
Filter Size21-1/2" x 16-3/8"
Heat Pump CompatibleYes
Includes Filter RackYes
Liquid Line FittingSweat or Braze
Liquid Line Size (OD)3/8"
Maximum Fuse Size15
Metering DeviceTXV/TEV - Thermostatic Expansion Valve
Minimum Circuit Amps5.4
PhaseSingle
Product FamilyFV4C
Prop 65Yes
RefrigerantR-410a
Rows3
Suction Line FittingSweat or Braze
Suction Line Size (OD)3/4"
TierPerformance
Tonnage1.5-3
UL ListedYes
UL RecognizedYes
Voltage208-230 VAC
Warranty OfferedNo

Ductless 24000 Btu Heat Pump Single Zone w/ Basepan Heater 208/230-1

Item: 38MAQB24R--3

Description

38MAQB24R--3
38 = OUTDOOR UNIT
MA = MODEL
Q = HEAT PUMP SYSTEM TYPE
B = 1:1 MAXIMUM NUMBER OF FAN COIL UNITS THAT CAN BE CONNECTED TO THE OUTDOOR UNIT
24 = 2 TON NOMINAL CAPACITY
R = HIGH HEAT UNIT TYPE
-- = NOT USED
3 = 208/230-1-60

The 38MA*R series ductless split systems are a matched combination of an outdoor condensing unit and an indoor fan coil unit connected only by refrigerant tubing and wires.The ductless system permits creative solutions to design problems such as:

  • Add-ons to current space (an office or family room addition)
  • Special space requirements
  • When changes in the load cannot be handled by the existing system
  • When adding air conditioning to spaces that are heated by hydronic or electric heat and have no ductwork

Historical renovations or any application where preserving the look of the original structure is essential.The ideal compliment to your ducted system when it is impractical or prohibitively expensive to use ductwork. The compact indoor fan coil units take up very little space in the room and do not obstruct windows. The fan coils are attractively styled to blend with most room decors. Advanced system components incorporate innovative technology to provide reliable cooling performance at low sound levels.

LOW SOUND LEVELS
When noise is a concern, the ductless split systems are the answer.The indoor units are whisper quiet. There are no compressors indoors, either in the conditioned space or directly over it, and there is none of the noise usually generated by air being forced through ductwork.
When sound ordinances and proximity to neighbors demand quiet operation, the 38MA*R unit is the right choice. The advanced, horizontal airflow design distributes air more evenly over the coil.
SECURE OPERATION
If security is an issue, outdoor and indoor units are connected only by refrigerant piping and wiring to prevent intruders from crawling through ductwork. In addition, since 38MA*R units can be installed close to an outside wall, coils are protected from vandals and severe weather.
FAST INSTALLATION
This compact ductless split system is simple to install. A mounting bracket is standard with the indoor units and only wire and piping need to be run between the indoor and outdoor units (High Walls).These units are fast and easy to install ensuring minimal disruption to customers in the home or workplace. This makes the 38MA*R ductless split systems the equipment of choice, especially in retrofit situations.
SIMPLE SERVICING AND MAINTENANCE
Removing the top panel on outdoor units provides immediate access to the control compartment, providing a service technician access to check unit operation. In addition, the draw-thru design of the outdoor section means that dirt accumulates on the outside surface of the coil. Coils can be cleaned quickly from the inside using a pressure hose and detergent.
On all indoor units, service and maintenance expense is reduced due to easy-to-use cleanable filters. In addition, these systems have extensive self-diagnostics to assist in troubleshooting.
BUILT-IN RELIABILITY
Ductless split system indoor and outdoor units are designed to provide years of trouble-free operation.
The indoor units include protection against freeze-up and high evaporator temperatures on heat pumps.
The condensing units on heat pumps are protected by a three minute time delay before the compressor starts the over-currentprotection and the high temperature protection.
INDIVIDUAL ROOM COMFORT
Maximum comfort is provided because each space can be controlled individually based on usage pattern. The air sweep (in some indoor models) feature provided permits optimal room air mixing to eliminate hot and cold spots for occupant comfort. In addition, year-round comfort can be provided with heat pumps.
ECONOMICAL OPERATION
The ductless split system design allows individual room heating or cooling when required. There is no need to run large supply-airfans or chilled water pumps to handle a few spaces with unique load patterns. In addition, because air is moved only in the space required, no energy is wasted while air moves through the ducts.
EASY-TO-USE CONTROLS
The indoor units have microprocessor-based controls to provide the ultimate in comfort and efficiency. The user friendly wireless remote control provides the interface between the user and the unit.
ACCESSORIES
Customizing these ductless split systems to your application is easily accomplished. Adding a condensate pump accessory to the indoor fan coil provides installation flexibility.
OPTIONAL WIRED CONTROLLER
AGENCY LISTINGS
All systems are listed with AHRI (Air Conditioning, Heating & Refrigeration Institute), and ETL.

Specifications

Weight145.5 Pounds (lbs)
Width37.24 Inches (In)
Height31.89 Inches (In)
Country of OriginCHN
Length16.14 Inches (In)
BrandBryant,Carrier
CertificationsAHRI Certified
CFM2130
Circuit Breaker - Max Amps30
Circuit Breaker - Min Amps20
ColorGray
Condenser Motor HP1/6 HP
Condenser Motor RPM1050
Condenser Motor TypeDirect Drive
Cooling Capacity24000
Cooling Rated Capacity Btu/h24000
Cycle/Hertz60 Hz
EER12.5
Energy Star RatedYes
ETL ListedYes
Heating Capacity24000
HSPF11.5
InverterYes
Liquid Line FittingFlare
Liquid Line Size (OD)3/8"
Maximum Piping Length98'
Number of HVAC Zones1
PhaseSingle
Product Family38MAR
Prop 65Yes
Rated Current Amps8.8
Rated Load Amps14
RefrigerantR-410a
SEER20
Single ZoneYes
Sound Level (dBA)60.5
StageVariable
Suction Line FittingFlare
Suction Line Size (OD)5/8"
TierPreferred™,Performance
Tonnage2
UL ListedNo
Voltage208-230 VAC
Warranty OfferedYes
Zone Capability1 Zone