Bryant® 5 Ton Packaged Rooftop Bundle - Gas Heat & Cool Rooftop (208/230-3), Low Leak Economizer and 14" Roof Curb

Item: BRY582KP06A31

Included In This Bundle

  • Cambridgeport Air Systems - 1023736 Ultra Low Leak Economizer
    Item: 1023736
    MFR: 1023736
    Quantity: 1
  • Cambridgeport Air Systems - 1000026 14" Curb for Rooftop Units
    Item: CRRFCURB001A00SL
    MFR: 1000026
    Quantity: 1
  • Bryant® Legacy™ - 5 Ton 14 SEER Gas Heat Packaged Rooftop Unit (208/230-3-60)
    Item: 582KP06A110A2A0AA
    MFR: 582KP06A110A2A0AA
    Quantity: 1

* Required Fields

Store Inventory

Sign in to see real-time inventory at the stores closest to you.
What’s the price?
Sign in for pricing.

Frequently Bought Together

Best Sellers

About This Product

Product Info

Description

PLEASE VERIFY VOLTAGE AND PHASE SELECTION PRIOR TO CHECKOUT
Warning: this product contains a chemical known to the State of California to cause cancer. P65Warnings.ca.gov

Specifications

BrandBryant
Prop 65Yes

Documents

Loading...

Bundle Components

Cambridgeport Air Systems - 1023736 Ultra Low Leak Economizer

Item: 1023736

Description

Ultra Low Leak Economizer

In many areas ultra low leak economizers are now required by code. Cambridgeport’s u.l.l. economizers meet and exceed the latest ASHRAE and IECC building codes. These economizers have been tested and labeled by an approved 3rd party testing facility in accordance with AMCA 500-d.

Specifications

Weight63 Pounds (lbs)
Width16.875 Inches (In)
Height17.5 Inches (In)
Country of OriginUSA
Length28.25 Inches (In)
Air FlowMulti-Position
BrandCambridgeport Air Systems
ColorGray
Cycle/Hertz60 Hz
For Use With3 - 6 Ton Roof Top Units
PhaseSingle
Prop 65Yes
Voltage120 VAC
Warranty OfferedYes

Cambridgeport Air Systems - 1000026 14" Curb for Rooftop Units

Item: CRRFCURB001A00SL

Description

Cambridgeport Air Systems - Cambridgeport's reliable and easy-to-install Curb Adapters mate any pre-existing roof curb to a new HVAC unit. They are designed and built to balance maximum air-flow performance with economy. Our Curb Adapters are one-piece welded construction with built-in supply transition, and always provide a water-tight seam
  • Engineered for low-static pressure
  • Even weight distribution to existing curb
  • Fabricated from heavy gauge, G90; galvanized steel body
  • All welds are sprayed with a galvanizing compound for rust protection
  • All curbs come with a factory-installed supply transition
  • Fully insulated with 1 - 1 ½ lb. density insulation
  • Shipped with easy-to-apply gasket material to seal HVAC unit to Adaptor
  • Specifications

    Weight180 Pounds (lbs)
    Width36.9375 Inches (In)
    Height14 Inches (In)
    Country of OriginUSA
    Length67.125 Inches (In)
    BrandCambridgeport Air Systems
    ColorGray
    CompositionGalvanized Steel
    Gauge18 GA
    Prop 65Yes

    Bryant® Legacy™ - 5 Ton 14 SEER Gas Heat Packaged Rooftop Unit (208/230-3-60)

    Item: 582KP06A110A2A0AA

    Description

    582KP06A110A2A0AA
    582 = Gas Heat RTU, Legacy™ Line / Unit Type
    K = Puron® (R-410A) Refrigerant / Model
    P = 208/230-3-60 / Voltage
    06 = 5 Tons / Cooling Tons
    A = Standard One Stage cooling models/Nat. Gas Heat / Refrig. System/Gas Heat Options
    110 = 110,000 / Heat Level Input (Three-Phase)
    A = Al/Cu - Al/Cu / Coil Options (RTPF) (Outdoor - Indoor)
    2 = Medium Static Vane Axial Fan Option / Indoor Fan Options
    A = Electro-mechanical controls. Allows for use of all field-installed economizers and dampers.
    0A = None / Factory Installed Options
    A = Standard Packaging, electro-mechanical controls, no intake or exhaust option. Will allow for use of all field-installed economizers, manual or 2-position damper.

    The new 3 to 6 Ton Legacy™ Line series Bryant rooftop units (RTU) with Axion™ Fan Technology were designed by customers for customers and integrates new technology to provide value added benefits never seen in this type of equipment before. New major design features include:
    • Patent pending, Industry’s first efficient indoor fan system using Vane Axial Fan with electric commutated variable speed motor.
    • Reliable fixed speed scroll compressor on 3-5 ton sizes and 2 stage scroll technology on 6 ton sizes.
    • Upgraded unit control board with intuitive indoor fan adjustment.
    • Reliable copper tube / aluminum fin condenser coil with 5/16 tubing to help reduce refrigerant charge verses prior designs.
    • New outdoor fan system with rugged – lightweight high impact composite fan blade.
    Installation ease
    All Legacy Line units are field convertible to horizontal air flow which makes it easy to adjust to unexpected job site complications. 582K/559K rooftop units up to 6 tons are specifically designed to fit on existing Bryant curbs dating back to 1989 for worry free original fit. Also, our large control box gives you room to work and room to mount Bryant accessory controls. Institutive controls make setting up the required fan speed simple and accurate. Access to blower section once required is not even required with the new design.

    Easy to maintain
    With the new Vane Axial fan and direct drive ECM motor - there is no longer a need to adjust belts or pulleys as in past designs.
    This frees up maintenance and installation time.
    Easy access handles by Bryant provide quick and easy access to all normally serviced components. Our "no-strip" screw system has superior holding power and guides screws into position while preventing the screw from stripping the unit’s metal.
    Sloped, corrosion resistant composite drain pan sheds water; and won’t rust.
    On 581K units the Bryant designed naturally draining heat exchanger, unlike positive pressure heat exchangers, does not need to be periodically, manually drained. This saves labor and maintenance expense.

    Easy to use
    The newly re-designed Unit Control Board by Bryant puts all connections and troubleshooting points in one convenient place. Most low voltage connections are made to the same board and make it easy to access it. Setting up the fan is simple by an intuitive switch and rotary dial arrangement. Bryant rooftops have high and low pressure switches, a filter drier, and 2-in. filters standard.

    Axion Fan Technology
    Direct drive Axion Fan Technology indoor fan system uses vane axial fan design and electrically commutated motors. This new Vane Axial design over past belt drive systems has 75% fewer moving parts, uses up to 40% less energy and has no fan belts, blower bearings and shaft.

    FEATURES/BENEFITS
    Design features include:
    • Single-stage units deliver SEERs up to 14.0 and EERs up to 11.8. Two-stage units deliver IEERs up to 15.2 and EERs up to 11.2.
    • All models are capable of either vertical or horizontal airflow.
    • The Bryant rooftop unit (RTU) was designed by customers for customers. With "no-strip" screw collars, handled access panels, and more the unit is easy to install, easy to maintain, and easy to use. Your new 3 to 6 ton Legacy Line Bryant rooftop unit (RTU) provides optimum comfort and control from a packaged rooftop.
    Value-added features include:
    • Optional Perfect Humidity™ dehumidification system for improved part load humidity performance
    • Puron® refrigerant (R-410A)
    • Single point gas and electrical connections
    • RTU Open controller for BACnet1, LonWorks2, Modbus3 and Johnson Controls N2
    • 3 to 5 ton models use fixed refrigerant metering devices and 6 ton models use a TXV
    • Scroll compressors with internal line-break overload protection
    Streamlined control and integration
    Bryant controllers make connecting Legacy™ Line rooftops into existing building automation systems easy. The units are compatible with conventional thermostat controls and Bryant RTU Open multi-protocol controller.

    Operating efficiency and flexibility
    The 582K/559K rooftops exceed ASHRAE (American Society of Heating, Refrigerating, and Air-Conditioning Engineers) 90.1-2016, IECC4 (International Energy Conservation Code) IECC-2018 minimum efficiency requirements.

    Field convertible airflow
    All Legacy Line 3 to 6 ton units are field-convertible to horizontal airflow, which makes it easy to adjust to unexpected job site complications.

    Comfort control
    Bryant's patented Perfect Humidity dehumidification system is an all-inclusive factory-installed option on gas heating/electric cooling and electric cooling/electric heat models. This system provides reliable, flexible operation to meet indoor part load sensible and latent requirements.

    Specifications

    Weight556 Pounds (lbs)
    Width46.625 Inches (In)
    Height33.375 Inches (In)
    Country of OriginMEX
    Length74.375 Inches (In)
    Air FlowConvertible
    Blower Motor HP1 4/9 BHP
    Blower Motor RPM239-2390
    Blower Motor SpeedsVariable
    Blower Motor TypeECM
    Blower Wheel16.6"
    BrandBryant
    Circuit Breaker - Max Amps50,45
    ColorGray
    CompressorScroll
    Condenser Motor HP1/4 HP
    Condenser Motor RPM1100
    Condenser Motor TypeDirect Drive
    Cooling Capacity58500
    Cooling Rated Capacity Btu/h60000
    Cycle/Hertz60 Hz
    Drain Connection Size3/4"
    Drive TypeDirect
    EER11
    Filter Size(2) 16" x 25" x 2" RA Filter, (1) 20" x 24" x 1" OA Inlet Screen
    Heating Capacity88000,65000
    Locked Rotor Amps110
    Maximum Fuse Size50,45
    Metering DeviceFixed Orifice
    Minimum Circuit Amps35,37,31,32
    PhaseThree
    Product Family582K
    Prop 65Yes
    Rated Load Amps16
    RefrigerantR-410a
    Sound Level (dBA)79
    StageSingle
    Thermal Efficiency80%
    TierLegacy™
    Tonnage5
    Voltage208-230 VAC
    Warranty OfferedYes

    Equipment Part List